CyberPower RB1280X2D bruksanvisning

CyberPower RB1280X2D
(1)
  • Sideantall: 1
  • Fyltype: PDF
+
-
-
+
-
+
-
+
1
32

MODEL: CP850AVRLCD, CP1000AVRLCD

1
2
3
1. Place the UPS on its top and remove the retaining screw (figure 1).
2. Slide the battery compartment cover completely off of the unit (figure 2).
3. Remove the battery from the compartment and disconnect the battery wires from the battery. Install the replacement
battery by connecting the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the
battery. (figure 3)
4. Slide the battery compartment cover over the battery and tighten the retaining screw.
5. Charge the unit for 4 – 8 hours to ensure the UPS performs expected runtimes.
1. Place the UPS on its side and locate the battery compartment cover on the bottom of the UPS. Remove the four (4)
retaining screws and pull the battery compartment cover off the UPS (figure 1 & 2).
2. Remove the battery from the compartment and disconnect the battery wires from the batteries. Install the
replacement batteries by connecting the red wire and black wire to the same color wires from the battery pack. Put
the battery pack into the compartment (figure 3).
3. Slide the battery compartment cover over the battery and tighten the retaining screw. Charge the unit for 4 – 8 hours
to ensure the UPS performs expected runtimes.
1. Carefully turn the UPS on its side. Remove the 6 retaining screws and the cover.
2. Disconnect the black and red cable from the battery set.
3. Remove the battery protection cover and take the battery pack out of the compartment.
4. Slide a new battery pack into the unit. Assemble the battery protection cover,cable, screws in the reverse order of
the previous steps. Recharge the unit for 4-8 hours to ensure the UPS performs expected runtime.
1. Carefully placed the UPS on its side. Remove the 2 retaining screws then push the battery cover backward and
remove the cover.
2. Disconnect the battery wires from the battery, and then remove the battery from the compartment.
REMINDER: For PP800/PP1100/PP1500T, 2 batteries are attached with one single plastic strip. You can pull the
plastic strip to pull out the battery.
3. Install the replacement battery by connecting the red wire to the positive (+) terminal of the battery and connecting
the black wire to the negative (-) terminal of the battery.
4. Slide the battery back into the compartment. Carefully turn the UPS upside down to help the batteries slide all the
way into the compartment. Replace the cover and the retaining screws. Recharge the unit for 4 – 8 hours to ensure
the UPS performs expected runtime.
1. Place the UPS on its side to locate and remove the front panel retaining screws from the bottom of the UPS.
2. Slide the cover (front panel) towards the bottom of the UPS.
3. Remove it from the unit.
4. Disconnect the cable located at the top of the cover.
5. Disconnect the battery wires from the batteries.
6. Remove the batteries from the compartment.
7. Install the replacement batteries by connecting the red and black wires to the same color wires from the battery
pack. Put the battery pack back into the compartment.
8. Replace the battery compartment cover and tighten the retaining screw. Charge the unit for 4-8 hours to ensure the
UPS performs expected runtimes.

Intelligent LCD Series

1
2
3
6
4
5

AVR Series

1
3 4
2

Professional Tower Series

MODEL: PP800SW

MODEL: PP1500SWT4, PP2200SW

1 2
4
3
K09-0000065-00

BATTERY REPLACEMENT

K09-0000065-00

BATTERY REPLACEMENT

MODEL: CP600LCD, CP825LCD, CP800AVR, CP685AVR-G, CP825AVR-G, CP685AVRLCD-G,

CP825AVRLCD-G

MODEL: CP900AVR, CP1200AVR, CP1500AVRT, CP1285AVRLCD, CP1350AVRLCD,

CP1500AVRLCD

CyberPower RB1280X2D

Trenger du hjelp?

Antall spørsmål: 0

Har du et spørsmål om CyberPower RB1280X2D eller trenger du hjelp? Still spørsmålet ditt her. Gi en tydelig og omfattende beskrivelse av problemet og spørsmålet ditt. Jo mer detaljert du beskriver problemet og spørsmålet, desto lettere blir det for andre eiere av CyberPower RB1280X2D å gi et godt svar på spørsmålet ditt.

Se håndboken for CyberPower RB1280X2D her gratis. Denne håndboken er under kategorien Batterier og har blitt vurdert av 1 personer med et gjennomsnitt på 8.3. Denne håndboken er tilgjengelig på følgende språk: Engelsk. Har du et spørsmål om CyberPower RB1280X2D eller trenger du hjelp? Still spørsmålet ditt her

Spesifikasjoner for CyberPower RB1280X2D

Generelt
Merke CyberPower
Modell RB1280X2D
Produkt Batteri
EAN 649532607853
Språk Engelsk
Fyltype PDF
Egenskaper
Batteriteknologi Forseglet blysyre (VRLA)
Batterikapasitet 8 Ah
Batterispenning 12 V
Kompatibilitet CP1285AVRLCD, CP1200AVR
Produktfarge Sort
Antall batterier inkludert 2 stykker
Vekt og dimensjoner
Vekt 5466 g
Bredde 202.1 mm
Høyde 63.5 mm
Dybde 150.9 mm
Miljømessige forhold
Driftstemperatur (T-T) 0 - 40 °C
Relativ luftfuktighet under drift (H-H) 0 - 90
Datainnpakking
Pakkebredde 304.8 mm
Pakkehøyde 93 mm
Pakkedybde 250 mm
Pakkevekt 6078 g
vis mer

Vanlige spørsmål

Nedenfor finner du de vanligste spørsmålene folk har om CyberPower RB1280X2D .

Finner du ikke spørsmålet ditt i listen? Still spørsmålet ditt her