Lenmar BCUNI3

Lenmar BCUNI3 bruksanvisning

(1)
  • Model BCUNI2 / BCUNI3
    All-in-One Battery Charger
    For Li-Ion, NiMH & AA/AAA Batteries
    Important Safety Instructions are included.
    Please read the entire manual before use.
    Owner’s Manual
    Thank you for purchasing the BCUNI2 / BCUNI3 Li-ion / NiCad /NiMH Battery Charger. The BCUNI2 /
    BCUNI3 provides the ability to charge battery packs externally for Camcorders, Digital Cameras and
    Mobile Phones plus charging for AA and AAA batteries. With the ease of adjustable contacts you are
    able to charge nearly all common Li-ion, NiCd and NiMH batteries. In addition the unit is able to
    charge USB equipment via its USB output port.
    Operating Instructions
    TECHNICAL SPECIFICATION
    Power Source: 12VDC, 100-240V AC and DC car cord plus EU & USA plugs included.
    Input Current: 1000mA
    Output Charging Current: 1000mA max. (3.6V Li-ion Battery) 1000mA max. (7.2V Li-ion Battery) 1000mA max.
    (Ni-CD/ Ni-MH battery)
    USB output: 5V/ 1000mA max.
    Charge Termination: 130mA max. (Li-ion Battery)
    Negative Delta V detection
    (Ni-CD/ Ni-MH battery)
    Timing Protection: Max. 7 hours (Li-ion battery)
    Max. 6 hours (NiCd/ Ni-MH Battery)
    LCD Indication: (BCUNI3)
    - Power status
    - Type of battery
    - Type of voltage
    - Battery capacity and charging status
    - Fault indication
    - USB port status (BCUNI3 ONLY)
    Dimension (Cover closed): L: 106mm X H: 30mm X W: 60mm
    Operating Temperature: 32° F~104º F (0º C~40º C)
    TROUBLESHOOTING
    NOTE: It is normal for the BCUNI2 /BCUNI3 to be warm during use.
    Notice
    Keep the BCUNI2 / BCUNI3 dry, if it gets wet wipe it dry immediately.
    Use and store it in normal temperature environments.
    Handle the BCUNI2 / BCUNI3 carefully, do not drop it. Do not use the BCUNI2 / BCUNI3 if
    the cords become damaged.
    Keep the BCUNI2 / BCUNI3 away from dust and dirt; wipe it with a cloth occasionally to keep it clean.
    There are no user serviceable parts inside! Modifying or tampering with its internal components can cause a
    malfunction and will invalidate its warranty. If your BCUNI2 / BCUNI3 is not performing as it should during
    the warranty period, contact Lenmar for warranty service.
    WARRANTY
    This limited warranty starts from the date of original purchase and expires 2 years thereafter.
    If, during this period, any part, because of manufacturing defects or workmanship fails to
    function properly under normal use will be repaired at no charge for parts and labor or, at our
    option, the product will be replaced. The following is excluded: damages from delay or loss of
    use of equipment, or damaged batteries, malfunctions resulting from misuse, tampering,
    unauthorized repairs, modifications, or accident. Package the unit and its accessories carefully
    using ample padding material to prevent damage in transit and ship it prepaid and insured to:
    LENMAR ENTERPRISES INC. USA
    4035 VIA PESCADOR
    CAMARILLO, CA 93012
    When sending in product for service you must first get a Return Authorization by visiting
    www.lenmar.com/warranty fill the out required form and our customer service reps will email
    you instructions on returning the item to us and issue a RETURN AUTHORIZATION NUMBER
    (RA) to be include on the box and any corresponding paper work. If you have any questions
    please call customer service at (805) 384-9600.
    All packages should include evidence of the date of purchase. Enclose $10.00 for shipping and
    handling for addresses in the US and $15.00 for addresses in Canada. For outside the US and
    Canada, freight will vary depending upon the ship to address.
    Proposition 65 Notice (California)
    The following statement is required in the state of California pursuant to the settlement of an
    action brought by the Mateel Environmental Justice Foundation against multiple electronics
    and appliance manufacturers
    WARNING: Handling the cord on this product will expose you to lead, a chemical known to
    the state of California to cause birth defects or other reproductive harm.
    Wash hands after handling.
    For further information contact
    Lenmar Enterprises, Inc.
    Product Service Department
    Phone: (800) 424-2703
    E-mail: sales@lenmar.com
    Visit Our Web Site at: www.lenmar.com
    1.
    2.
    3.
    4.
    310-058-35-0315 r1
    POWERED BY
    Inserting the Desired Battery to Charge.
    With the sliding cover extended insert the
    battery into the BCUNI2 / BCUNI3, slide the
    battery back about 1/8 of an inch so you are
    able to see the contacts on the battery as well
    as the contacts on the charger. Manually
    adjust the contacts on the charger to meet
    the contacts on the battery. If needed adjust
    the height of the contacts by using the
    adjusting dial until the chargers contacts
    meet the batteries contacts.
    Adjusting the Sliding Cover.
    For small or standard batteries, just simply pull
    back the sliding cover. If your battery is larger,
    you will need to press down the release
    button which allows the sliding cover to
    extend up to 3 inches, allowing you to charge
    longer batteries.
    Adjusting Contact Positions for Charging.
    By manually moving the contact adjusters left
    and right you are able to adjust the contacts
    to your desired width to accommodate the
    positive and negative terminals. Then with the
    adjusting dial you are able to raise and lower
    the contacts allowing the contacts to touch
    the positive and negative terminals.
    Charging AA and AAA Rechargeable Batteries.
    You can charge either one or two batteries at a
    time by sliding back the cover. Insert either one
    battery by using the right channel or two
    batteries by using both channels. (see diagram)
    again use the adjusting dial to either raise or
    lower the charger contacts to meet the batteries
    contacts. Pay attention to the polarity markings
    on the channel of the charger.
    Note:
    Do not mix cells type in the charging bays. Cells must be inserted in the charging bays must be the same size, capacity and
    chemistry. (I.e. NiCd or NiMH) The charger may malfunction with mixed cell types or capacities in the charging bays and damage the
    cells permanently.
    USB PORT. (BCUNI3 ONLY)
    The USB port allows
    simultaneous charging of your
    mobile phone, MP3
    & other handheld devices.
    LED Power Indicator.
    (BCUNI2 ONLY)
    There is a BLUE LED power
    indicator on the face of
    the BCUNI2.
    LCD Display.
    (BCUNI3 ONLY)
    RELEASE BUTTON
    ONE CELL CHARGING TWO CELL CHARGING
    ADJUSTING DIAL
    CONTACT ADJUSTER
    USB PORT
    POWER LED INDICATOR
    CHEMISTRY
    CHEMISTRYVOLTAGE
    FA ULT
    CAPACITY/
    CHARGING STATUS
    USB ACTIVE POWER UP
    LCD DISPLAY
    Chemistry of battery pack that is charging:
    Either Li-Ion or NiCd/NiMH
    Battery Voltage:
    1.2, 2.4, 3.6, 4.8, 6.0 or 7.2 V
    Fault:
    If the battery is defective or inserted incorrectly
    Battery Capacity and charging status:
    Displayed with a four bar graph that shows
    charging capacity status
    USB Active Symbol:
    This will show if the USB port is in use
    Power Symbol:
    This show the unit has power
    The SCREEN will display the following:
    (BCUNI3 ONLY)
    Power:
    Blue LED indicator
    Charging:
    Flashing blue LED indicator
    Full charge:
    Solid Blue LED indicator
    Fault:
    Flashing red LED
    (BCUNI2 ONLY)

Trenger du hjelp?

Antall spørsmål: 0

Har du et spørsmål om Lenmar BCUNI3 eller trenger du hjelp? Still spørsmålet ditt her. Gi en tydelig og omfattende beskrivelse av problemet og spørsmålet ditt. Jo mer detaljert du beskriver problemet og spørsmålet, desto lettere blir det for andre eiere av Lenmar BCUNI3 å gi et godt svar på spørsmålet ditt.

Se håndboken for Lenmar BCUNI3 her gratis. Denne håndboken er under kategorien Batteriladere og har blitt vurdert av 1 personer med et gjennomsnitt på 5.7. Denne håndboken er tilgjengelig på følgende språk: Engelsk, Fransk, Spansk. Har du et spørsmål om Lenmar BCUNI3 eller trenger du hjelp?

Spesifikasjoner for Lenmar BCUNI3

Merke Lenmar
Modell BCUNI3
Produkt Batterilader
EAN 29521840926, 295218409268
Språk Engelsk, Fransk, Spansk
Fyltype PDF
Energihåndtering
Utgangsstrøm 3.6V
Inngangsfrekvens 50/60Hz
Battery
Batterier inkludert
Design
Produktfarge Svart
Egenskaper
Antall støttede batterier 2
Kompatible batteriteknologier Lithium-Ion (Li-Ion), Nickel-Metal Hydride (NiMH)
Kompatible batteristørrelser AA, AAA
Ytelse
Modell/Type Innendørs

Relaterte produkter Lenmar BCUNI3

    Relaterte produkthåndbøker

    Batterilader Lenmar

    Legg til håndbok

    Har du en håndbok som du vil legge til?